ESTAPLACE.COM REAL ESTATE - FREE LISTING SERVICE - is an accommodation and real estate directory, where real estate property owners or real estate agencies connect with vacationers and home buyers worldwide. If you are a seller, you can add listings in few seconds, and if you are a buyer you can search listings to find your dream property!

Search by keywords or by a location.

You can also browse our web directory.


Search on 41274 Newsgroup messages
[ Tue, 31 May 2005 19:06:21 -0500 ] [ 153238 ] [ alt.building.construction ] [ view full article ]
Duane Bozarth - Re: Strengthening floor above garage - Jeff P wrote: .... > I thought this newgroup would be helpful but apparently I misunderstood the > topic. May I ask what the purpose of this group is then? Discussion, not design. You've gotten some ideas, but the possibility of making a really definitive recommendation in this forum is just not there... Certainly no registered engineer dare risk such advice and others may (...
[ ] [ 153237 ] [ alt.building.construction ] [ view full article ]
"Doug B Taylor" - Re: Subpanel help - "NuckinFutz" wrote in message news:EU4ne.3137$xD2.2535@fe02.lga... > Well it WAS a break in the underground cable. New run of 10/3 solved the > problem. Now to bury the cable in conduit or not is the question. > > Jeff, > Jeff - Seems to me your experience should answer your own question. If the original cable was in conduit it would have been a...
[ ] [ 153236 ] [ alt.building.construction ] [ view full article ]
"NuckinFutz" - Re: Subpanel help - No I dont know it all and no I certainly dont need advice from you and yes I will ignore you from now on. You're about as usefull as Lyle Adios for good . ...
[ ] [ 153235 ] [ alt.building.construction ] [ view full article ]
"NuckinFutz" - Re: Designing an insulated shed - Harry You dont need an attic. In fact I would take the space under the roof and use it for storage. I would just insulate betwen the joists with either sprayed foam or batts. The real issue will be condensation removal which can be handled a number of diffrent ways. If you use batts then a traditional soffit will work fine. Beleive it or not the majority of water vapor on t...
[ Tue, 31 May 2005 16:52:37 -0500 ] [ 153233 ] [ alt.building.construction ] [ view full article ]
Duane Bozarth - Re: Strengthening floor above garage - Jeff P wrote: > .... > I suppose I could notch out the top plate that the joices currently rest... ...snip... The word is "joist".... I agree w/ tbasc and Bob Morrison... . ...
[ ] [ 153232 ] [ alt.building.construction ] [ view full article ]
"NuckinFutz" - Re: Subpanel help - Well it WAS a break in the underground cable. New run of 10/3 solved the problem. Now to bury the cable in conduit or not is the question. Jeff, Just saving a couple of pennies is all. 2 30amp legs is more than I'll need in the shed. I have one 220v 15 amp table saw, a 20amp air compressor, a 110v lathe that draws less than 15 amps, a bench top drill press, a miter saw t...
[ Tue, 31 May 2005 21:35:42 GMT ] [ 153231 ] [ alt.building.construction ] [ view full article ]
Bob Morrison - Re: Strengthening floor above garage - In a previous post says... > I'm suggesting a floor structure separate from the roof structure. > I'd suggest sistering the new 2x12s to the existing 2x8s. > > A few hundred dollars would pay a structural engineer for a > consultation. > It would save thousands of dollars in damage. > Amen! There is more to this than just a quick response via newsgroup. Hire a local ...
[ 31 May 2005 14:11:48 -0700 ] [ 153229 ] [ alt.building.construction ] [ view full article ]
tbasc@bellsouth.net - Re: Strengthening floor above garage - I'm suggesting a floor structure separate from the roof structure. I'd suggest sistering the new 2x12s to the existing 2x8s. A few hundred dollars would pay a structural engineer for a consultation. It would save thousands of dollars in damage. TB . ...
[ Tue, 31 May 2005 16:46:26 -0400 ] [ 153227 ] [ alt.building.construction ] [ view full article ]
"Jeff P" - Re: Strengthening floor above garage - wrote in message news:1117564646.465342.282700@o13g2000cwo.googlegroups.com... >A 2x12 of #2 Southern Yellow Pine @ 16 inches on center will hold 40 > lbs per square foot live load. > (Canadian Wood Council) > A 2x12 can be notched 2 7/8 inches at the ends. > (Western Wood Council) > TB > Notched 2 7/8" at the ends? That is kind of a problem because a...
[ Tue, 31 May 2005 20:15:05 GMT ] [ 153225 ] [ alt.building.construction ] [ view full article ]
Ren@tionalisebritishtele.com - Re: Beehive in Soffit - On 23-May-2005, "Maverick" wrote: > There is no way an average citizen (I hate that term) can tell a killer > bee > from a friendly bee. Be glad you're a citzen, even if you're an average one. In the UK we are subjects of Her Majesty the Queen. Steve . ...
[ Tue, 31 May 2005 13:32:58 -0500 ] [ 153223 ] [ alt.building.construction ] [ view full article ]
"Gymfolks" - Sewer Tie-In Question - I have a 16" sanitary sewer line (and easement) running beneath the dry creek bed on my property. My new house will be on the ridgeline (up some 40 feet up) overlooking the dry creek bed. The ridgline is quite steep, but the soil would be trenchable (nice black dirt) if the trencher could be lowered down via a chain/cable from a dozer. Has anybody ever dealt with this sort of proble...
[ Tue, 31 May 2005 11:08:40 -0700 ] [ 153222 ] [ alt.building.construction ] [ view full article ]
"Dan Deckert" - Re: chain link fence - "Dan" wrote in message news:LT0ne.86001$w15.77320@tornado.tampabay.rr.com... > A couple of questions: > > 1) I want to build a 10' gate using the gate ell's and 10' rails. Is there > any way to cross brace it so it doesn't sag? Maybe using a wire strung > diagonally from the top ell near the post to the bottom ell of the other > end? In the com...
[ ] [ 153220 ] [ alt.building.construction ] [ view full article ]
"NuckinFutz" - Re: Subpanel help - It seems at this point that its a short in the underground cable running out to the shed. If I disconnect the cable at the sub panel it shorts out. If I disconnect the cable at the main breakers it doesnt short out Well I guess i'll be running new 10/3 this time. I still cant figure out how the cable could have broken under ground. I buried the damn thing almost five feet dee...
[ 31 May 2005 08:15:45 -0700 ] [ 153217 ] [ alt.building.construction ] [ view full article ]
"butch burton" - Re: Minimum pitch for shingled roof - Sorry - I mean using the ice damming material as a means to help insure against leaks. Hopefully no ice dams if I get the circulation correct - that will be another challenge. . ...
[ Tue, 31 May 2005 09:54:42 -0400 ] [ 153215 ] [ alt.building.construction ] [ view full article ]
"NuckinFutz" - Re: Subpanel help - "Lil' Dave" wrote in message news:a9Yme.11103$M36.1083@newsread1.news.atl.earthlink.net... > "NuckinFutz" wrote in message > news:xCMme.17602$cP2.4956@fe06.lga... >> OK I've shot my load hehehehe >> >> I screwed up and only ran 10/2 from my main panel out to my subpanel >> which >> is in a shed. >> >> So far I've put in my feed...
[ Tue, 31 May 2005 11:47:18 GMT ] [ 153214 ] [ alt.building.construction ] [ view full article ]
"Lil' Dave" - Re: Subpanel help - "NuckinFutz" wrote in message news:xCMme.17602$cP2.4956@fe06.lga... > OK I've shot my load hehehehe > > I screwed up and only ran 10/2 from my main panel out to my subpanel which > is in a shed. > > So far I've put in my feeder breaker (30 amps) out to the subpanel. > > At the main panel the black and white wires are my hot wires (from the ...
prev page  [258] [259] [260] [261] [262] [263] [264] [265] [266] [267] [268] [269] [270] [271] [272] [273] [274]  next page



[ USA -> CHICAGO - 25/June/2026 04:26:47 ] We have 24810 properties listed. Yesterday traffic on Estaplace Real Estate was: 10970 unique visitors with 196208 page views. To view more statistics about Estaplace Real Estate, click here.

We accept, payments through bank wire, credit cards with PayPal for advanced services! PayPal Gateway Visa Card MasterCard American Express Diners Card Jcb Credit Card PostaPay Maestro Pago Bancomat Hosted by Frazionabile.it

Estaplace.com is a worldwide and international real estate directory, with thousands of real estate listings, divided into countries and regions. All material, the structure, and the layout on this site are © Copyright of Estaplace.com by Ceglia Giovanni located in Trento N. 74 Pal. I Street in Pagani(Salerno) - Italy. Italian Business Code: Partita IVA N. IT03972320653, registered in the "Camera di Commercio" of Salerno.

Estaplace.com is one the Ceglia Giovanni projects, started on 20 July 2005, and online since 20 August as a real estate platform for listings, mainly operating on the Italian and American/English market in the Internet, Estaplace would like to become the point of referiment for home sellers and home buyers, a site where private owners or real estate agencies can have the possibility to show their offers to the world. Estaplace.com is only one of the Giovanni Ceglia's sites. Everyday Giovanni Ceglia works to improve new Internet tools and services for online marketing and business. Estaplace.com will become the biggest portal for real estate business and investments online.