![]() |
|
|
|
[ 27 Oct 2005 07:37:20 -0700
] [ 158470 ] [ alt.building.construction ] [ view full article ] michael.cumming@gmail.com - Re: suggestions for air temperature measurement - posting-account=yCVerw0AAABA1IEHEOJnOmILrhyDXVxF Xref: authen.white.readfreenews.net alt.building.construction:158470 sci.geo.meteorology:103525 comp.home.automation:192589 . 221 158470 <1130423840.464689.324030@g43g2000cwa.googlegroups.com> head Path: authen.white.readfreenews.net!green.octanews.net!news-out.octanews.net!news.glorb.com!postnews.google.com!g43g2000cwa.googlegroups.com!n... |
[ Thu, 27 Oct 2005 07:11:55 -0700
] [ 158467 ] [ alt.building.construction ] [ view full article ] "Dan Deckert" - Re: confused on NEC for grounding garage - Path: authen.white.readfreenews.net!green.octanews.net!news-out.octanews.net!news.glorb.com!border1.nntp.dca.giganews.com!nntp.giganews.com!local01.nntp.dca.giganews.com!nntp.owt.com!news.owt.com.POSTED!not-for-mail NNTP-Posting-Date: Thu, 27 Oct 2005 09:11:14 -0500 From: "Dan Deckert" |
[ Thu, 27 Oct 2005 09:12:20 -0400
] [ 158465 ] [ alt.building.construction ] [ view full article ] "Jeff" - Re: Shower basin - Look at this .pdf: http://www.oatey.com/shower_drains/lit/Shower%20Pan%20Liner.pdf very complete with illustrations. Jeff "Jeff and Jennifer Cook" |
[ Thu, 27 Oct 2005 08:11:19 -0400
] [ 158463 ] [ alt.building.construction ] [ view full article ] "Dennis Brothers" - Re: suggestions for air temperature measurement - "Marc F Hult" |
[ Thu, 27 Oct 2005 12:03:27 GMT
] [ 158461 ] [ alt.building.construction ] [ view full article ] "Borg hater" - Re: confused on NEC for grounding garage - Prefer to think the grounding rod need in this fashion: Electricity will take both the least resistant and shortest path to ground. If there is no grounding rod at the garage, and a mutual hot and grounding wire break and contact occurs near or at the garage, the current flow will have to go all the way back to the house grounding rod. This will give it more time for wire meltdown befor... |
[ ] [ 158459 ] [ alt.building.construction ] [ view full article ] Reg - Re: suggestions for air temperature measurement - Marc F Hult wrote: > Thanks for the suggestion. The mcs plug-in seems intrinsically very capable > from what I could tell. > > But I poked around the Homeseer site longer than I had patience for without > finding a manual or any actual description. Did I miss it? And no url for a > mcs web site. Apparently I have to download Homeseer (yet again), install > it (yet again) and th... |
[ Wed, 26 Oct 2005 21:09:30 -0500
] [ 158457 ] [ alt.building.construction ] [ view full article ] "James T. White" - Re: Shower basin - "Jeff and Jennifer Cook" |
[ Thu, 27 Oct 2005 01:59:54 GMT
] [ 158455 ] [ alt.building.construction ] [ view full article ] "Gary Lee" - Re: Roofer's Contract Spec'ed #30 felt paper, but used #15 instead -- Suggestions? - "Dennis" wrote > Most likely they used two layers of 15# felt. (actually it's required in > Ohio because for ice protection at the eaves.) The felt is double layered > and cemented together up to a point 24in. in from the exterior walls. If > the roof slope is 2:12 up to 4:12 (low-slope) a double layer is still > required for the rest of the roof (otherwise 15# will be code). > Ab... |
[ Thu, 27 Oct 2005 01:19:25 GMT
] [ 158452 ] [ alt.building.construction ] [ view full article ] "Dennis" - Re: Roofer's Contract Spec'ed #30 felt paper, but used #15 instead -- Suggestions? - Most likely they used two layers of 15# felt. (actually it's required in Ohio because for ice protection at the eaves.) The felt is double layered and cemented together up to a point 24in. in from the exterior walls. If the roof slope is 2:12 up to 4:12 (low-slope) a double layer is still required for the rest of the roof (otherwise 15# will be code). About the only way you can tell... |
[ Thu, 27 Oct 2005 00:58:21 GMT
] [ 158450 ] [ alt.building.construction ] [ view full article ] "Dennis" - Re: RV electric - You would have two legs feeding 50 amps per leg. Between the two legs you have 240 volts, and between either leg and the white, grounded conductor (called a neutral in a 240 volt circuit- there's no neutral in a 120 volt circuit) you would have 120 volts. If you have access to the NEC, Article 551 covers Rec Vee electrical installations and Article 552 covers Park Trailer electrica... |
[ Thu, 27 Oct 2005 00:21:34 GMT
] [ 158448 ] [ alt.building.construction ] [ view full article ] "Dennis" - Re: Where to find roller parts for fireplace? - Contact these people http://www.fireplacesandgrills.com/ > I have a very old fireplace, installed in the seventies. > > It has what I think is a very flimsy mechanism for the > screen to keep the sparks in. > > The screen hangs on rollers like this one: > > Does anyone know the name of this kind of part? > > Where could I find one made out of metal? > > > Thanks > ... |
[ 26 Oct 2005 16:19:44 -0700
] [ 158446 ] [ alt.building.construction ] [ view full article ] "Rich-out-West" - Re: Framing for shed - Bob Morrison wrote: >snip< Straight studs 14-16 feet long are > possible but you will have to get them from a lumber yard and not one of > the big box stores. > > -- > Bob Morrison, PE, SE > R L Morrison Engineering Co > Structural & Civil Engineering > Poulsbo WA Sometime last year, I made a great "discovery"... Our outstanding local lumberyard (Cascade ... |
[ ] [ 158443 ] [ alt.building.construction ] [ view full article ] Marc F Hult - Re: suggestions for air temperature measurement - On 26 Oct 2005 10:26:56 -0700, "lelson@bigfoot.com" |
[ Wed, 26 Oct 2005 20:04:15 GMT
] [ 158440 ] [ alt.building.construction ] [ view full article ] Bob Morrison - Re: Framing for shed - In a previous post Budman wrote... > If I collar-tie all the rafters and use a double 2x6 top plate, will it > be enough to resists the push of the rafters against the exterior > walls? Can you find straight enough 14-16ft 2x6 studs (non-engineered) > to do this? > The short answer is "maybe". The "push-out" problem depends a great deal on the magnitude of your snow load. Stra... |
[ Wed, 26 Oct 2005 14:30:18 -0500
] [ 158438 ] [ alt.building.construction ] [ view full article ] "amcwill417" - Re: suggestions for air temperature measurement - |
[ Wed, 26 Oct 2005 18:21:14 GMT
] [ 158436 ] [ alt.building.construction ] [ view full article ] "PipeDown" - Re: Shower basin - "Jeff and Jennifer Cook" |
|
<Rentals>
<House Exchanging>
<Frequently Asked Questions>
<Add Article>
<Help>
<Terms & Conditions>
<Guestbook>
<Prices>
<Tips on writing your listing>
<Real Estate Forums>
<News>
<Press Room>
<Success Stories>
<Estaplace.com History>
<Webmaster's Tools>
<Copyright>
<About Our Team>
<Search Real Estate Agents>
<E-Mail Us>
[ USA -> CHICAGO - 20/July/2025 08:28:45 ]
We have 24807 properties listed. Yesterday traffic on Estaplace Real Estate was: 3292
unique visitors with 227814 page views. To view more statistics about
Estaplace Real Estate, click here.
|
Estaplace.com is a worldwide and international real estate directory, with thousands
of real estate listings, divided into countries and regions. All material, the structure, and the layout on this site
are © Copyright of Estaplace.com by Ceglia Giovanni located in Trento N. 74 Pal. I Street in Pagani(Salerno) - Italy.
Italian Business Code: Partita IVA N. IT03972320653, registered in the "Camera di Commercio" of Salerno.
Estaplace.com is one the Ceglia Giovanni projects, started on 20 July 2005, and online since 20 August as a real estate platform for listings, mainly operating on the Italian and American/English market in the Internet, Estaplace would like to become the point of referiment for home sellers and home buyers, a site where private owners or real estate agencies can have the possibility to show their offers to the world. Estaplace.com is only one of the Giovanni Ceglia's sites. Everyday Giovanni Ceglia works to improve new Internet tools and services for online marketing and business. Estaplace.com will become the biggest portal for real estate business and investments online.
Estaplace.com is one the Ceglia Giovanni projects, started on 20 July 2005, and online since 20 August as a real estate platform for listings, mainly operating on the Italian and American/English market in the Internet, Estaplace would like to become the point of referiment for home sellers and home buyers, a site where private owners or real estate agencies can have the possibility to show their offers to the world. Estaplace.com is only one of the Giovanni Ceglia's sites. Everyday Giovanni Ceglia works to improve new Internet tools and services for online marketing and business. Estaplace.com will become the biggest portal for real estate business and investments online.